Audiovox AS9050 Key Fob Programming Instructions

This Audiovox AS9050 system uses replacement remote: ELVATCC, AVX1B4S, AVX-1B4S

PROGRAMMING INSTRUCTION FOR THE REMOTE:

This type of remote is designed for your upgrade remote start system and was programmed by using the remote start’s valet switch/button in combination with the remote button. Although this remote can be programmed into any of the Audiovox remote start and or alarm, alarm remote start system, it will still offer limited use and should be used for the remote start upgrade only.

1) Twist the key in the ignition to ON position
2) Press the valet button/switch 3 times
3) Press and hold the button of the remote for 3 seconds which you wish to add until the parking light flashes.
4) Go back to step 3 for each remote (a maximum of 4). Turn the ignition off to exit the program mode.

ATTENTION:  Do not allow more than 15 seconds to lapse between steps or the program mode will be automatically turn off and you will need to start from the top.